Transportation BOX PC Solutions Model AEV-6356 System Processor Intel® Core™ i7-3517UE up to 2.8 GHz, Intel® Celeron® 827E, 1.4 GHz Chipset Intel® QM77 System Memory DDR3 SODIMM x 1, up to 8 GB Display Interface DB-15 x 1 for VGA DVI-D x 1 Storage Device CFast™ x 1, SATA 6.0 Gb/s x 2 (Support RAID 0,1) Front I/O connector USB 2.0 x 2 (M12), RS-232/422/485 x 1 (M12), Giga LAN x 2 (M12), VGA x 1 (DB-15), DVI-I x 1, Power button, CFast™ slot x 1, SIM card slot x 1 Rear I/O connector Digital input x 6, Digital output x 2, USB 3.0 x 2 (Type A), RS-232 x 2 (DB-9), RS-232/422/485 x 1 (DB-9, Isolated), Line-out x 1, mic x 1, Power input (17 ~ 30VDC) (M12) Digital Input Isolated digital input Max. voltage input: Logic level 0: +2.5 V max. Logic level 1: +5 V Digital Output Isolated digital output Max. frequency of IDO Max. voltage output: +5 V, Max. current output: 50mA Isolated 5V Output (with short protection) Max. voltage output: +5 V max. Max. current output: 200mA Serial Interface RS-485: isolated 1000VDC (Rear I/O) Expansion Slot Full-size Mini-PCIe x 1, Half-size Mini-PCIe x 1 (WiFi/ 3G/ GPS)(Optional) Indicator System LED x 1 OS Support Window® XP Embedded, Window® XP, Windows® 7, Window® Embedded Standard 7, Linux Fedora Mechanical Mounting Wallmount Dimension 11.26” x 6.46” x 3.62” (286mm x 164.2mm x 92mm ) Gross Weight 15.4 lb (7 kg) Net Weight — Power Supply DC Input DC 17 ~ 30V (M12) Over-voltage protection, Low-voltage protection, Short circuit protection Environment Test System Operation Temperature -40°F ~ 158°F(-40°C ~ 70°C)(85°C for 10 Minutes), EN500155 Tx Humidity Conforms to EN 50155/EN50125-1, Test method EN 60068-2-30 (variant 1): Yearly average at 75 % HR, 30 days at 95 % HR, Occasionally at 100 % HR Tropicalisation and mist constraints Insulation Resistance Conforms to EN50155 Voltage withstand Conforms to EN50155, Power supply voltage range 0.7u < u < 1.25u, u = normal Voltage, 24V Mechanical Earth Continuity Compliant with EN50155 standard Pollution Compliant with: EN60721-3-5 standard EMC Compliant with EN50121 standard ESD Conforms to EN 50155 Radiated Electromagnetic Fields Radiated immunity test method EN 61000-4-3: The frequency range for the tests shall be done until 2.4 GHz, and an attenuation of 20 V/m. Immunity To Fast Transients Bursts Conforms to Standard reference: EN 50155 (§ 10.2.7) / EN 50121-3-2 Fast transient burst immunity, Test method EN 61000-4-4, ± 2kV- repetition frequency: 5 kHz, ports referenced to the battery: direct injection, other signals: capacitive coupling. Surges Immunity Standard reference: EN 50155 (§ 10.2.6.2) / EN 50121-3-2 Surge immunity, Test method EN 50155 ±1kV Conducted Disturbances Induced By Radio-Frequency Fields Test method EN 61000-4-6, 150kHz-80MHz 1kHz, 80%AM, 10 Vrms Emission Measurement Conducted emissions standard reference: EN 50155 (§ 10.2.8.2) / EN 50121-3-2 radiated emission, Test method EN 55011, Class A, 30MHz-230MHz 40dBµV, 230MHz-2.4GHz 47dBµV. Shocks and Vibrations Test method EN 61373 (random vibration), operating test (duration > 10 min), Frequency range = 5-150 Hz, 0,7 m/s2 (longitudinal & transversal axis), 1 m/s2 Test method EN 61373 (random vibration), frequency range = 5-150 Hz, Test with equipment powered down for 5 hr, 5,5 m/s2 (longitudinal & transversal axis). Test method EN 61373 (random vibration), 50 m/s2 for 30 ms (longitudinal & transversal axis), 30 m/s2 for 30 ms (vertical axis), 3 shocks x 2 directions x 3 axes = 18 shocks Certification CE, FCC, EN50155, EN50121, EN45545 29 Note: All specifications are subject to change without notice. Selection Guide