www.advantech.com/products Online Download ADAM-6260 ADAM-6266 ADAM-6260 ADAM-6266 6-ch Relay Output Modbus TCP Module 4-ch Relay Output Modbus TCP Module with 4-ch DI Specifications Relay Output Channels ADAM-6260: 5 Form C and 1 Form A ADAM-6266: 4 Form C Contact Rating (Resistive) 250 VAC @ 5A 30 VDC @ 5A Max. Switching Voltage 400 VAC 300 VDC Breakdown Voltage 500 VAC (50/60Hz) Max. Breakdown Capacity 1250 VA Frequency of Operation 360 operations/hour with load 72,000 operations/hour without load Set/Reset Time 8 ms/8 ms Mechanical Endurance > 15 x 106 operations Isolation between Contact 1000 Vrms Insulation Resistance > 10 GΩ @ 500 VDC Digital Input Channels ADAM-6266: 4 Dry Contact Logic 0: Open Logic 1: Closed to DI COM Wet Contact Logic 0: 0 ~ 3 VDC or 0 ~ -3 VDC Logic 1: 10 ~ 30 VDC or -10 ~ -30 VDC (Dry/Wet Contact decided by Switch) Input Impedance 5.2 kW (Wet Contact) Transition Time 0.2 ms Frequency Input Range 0.1 ~ 3kHz Counter Input 3kHz (32 bit + 1 bit overflow) Keep/Discard Counter Value when power off Supports Inverted DI Status Ordering Information ADAM-6260 6-ch Relay Output Modbus TCP Module ADAM-6266 4-ch Relay Output Modbus TCP Module with 4-ch DI Common Specifications General Ethernet 2-port 10/100 Base-TX (for Daisy Chain) LED Indication ADAM-6260: 6 RL ADAM-6266: 4 RL + 4 DI Protocol Modbus/TCP, TCP/IP, UDP, HTTP, DHCP Connector Plug-in 5P/15P screw terminal blocks Power Input 10 - 30 VDC (24 VDC standard) Watchdog Timer System (1.6 seconds) Communication (Programmable) Dimensions 70 x 122 x 27 mm Protection Built-in TVS/ESD protection Power Reversal protection Over Voltage protection: +/- 35VDC Isolation protection: 2500 VDC Power Consumption ADAM-6260: 4.5 W @ 24 VDC ADAM-6266: 4.2 W @ 24 VDC Features Daisy chain connection with auto-bypass protection Remote monitoring and control with smart phone/pad Group configuration capability for multiple module setup DI/O LED Indication Flexible user-defined Modbus address. Intelligent control ability by Peer-to-Peer and GCL function Multiple protocol support: Modbus TCP, TCP/IP, UDP, HTTP, DHCP Web language support: XML, HTML 5, Java Script System configuration backup User Access Control Environment Operating Temperature -10 ~ 70°C (14 ~ 158°F) Storage Temperature -20 ~ 80°C (-4 ~ 176°F) Operating Humidity 20 ~ 95% RH (non-condensing) Storage Humidity 0 ~ 95% RH (non-condensing) Power & Energy Automation 8 5 4 4 10 Panel PCs 9 iDoor Technology Modules 8 Industrial monitors 7 Industrial IoT Gateways 6 Control Cabinet PCs High-Performance Control Panels Industrial Operator Panels 3 2 IntelligentMotionControl andMachineVision 1 11 Control IPCs 12 Remote DA&C Systems 13 Wireless IoT Sensing Devices 14 Ethernet I/O Modules 15 RS-485 I/O Modules 16 Thin-Client Terminals Industrial Ethernet Solutions 17 IP Gateway and Serial Device Servers iNetworking 18 19 WebAccess+ Solution Chapter 15 Table of Contents Table of Contents