2-8 www. m oxa. com Industry-Specific Ethernet Switches > TN-5916 Series 2 Industry-Specific Ethernet Switches Ordering Information Optional Accessories (can be purchased separately) Power Cords, M12/M23 Connectors, Protective Caps: See the EN 50155 Switch Accessories datasheet for details MXview: Moxa industrial network management software with 50, 100, 250, 500, 1000, or 2000 nodes EDS-SNMP OPC Server Pro: OPC server software that works with all SNMP devices ABC-01-M12: Configuration backup and restoration tool for TN series managed Ethernet routers, 0 to 60°C operating temperature Package Checklist • TN-5916 router • M12-to-DB9 console port cable • 2 protective caps for console and relay output ports • Panel-mounting kit • Documentation and software CD • Hardware installation guide • Warranty card Available Models Port Interface Power Supply Conformal Coating Wide Temperature (-40 to 75C) Front Cabling 10/100BaseT(X), M12 connector 10/100BaseT(X), M12 connector with bypass relay 10/100/1000 10/100BaseT(X), M12 connector 10/100/1000BaseT(X), M12 connector with bypass relay WV: 24 to 110 VDC (16.8 to 137.5 VDC) TN-5916-WV-T 16 4 – – 1 (Dual Input) – TN-5916-WV-CT-T 16 4 – – 1 (Dual Input)  Overload Current Protection: Present Connection: M23 connector Reverse Polarity Protection: Present Physical Characteristics Housing: Aluminium alloy IP Rating: IP54 protection (optional protective caps available for unused ports) Dimensions: 250 x 175.8 x 116.3 mm (9.84 x 6.92 x 4.58 in) Weight: 4030 g (8.88 lb) Installation: Panel mounting, DIN-rail mounting (with optional kit) Environmental Limits Operating Temperature: Wide Temp. Models: -40 to 75°C (-40 to 167°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Altitude: 2,000 m Standards and Certifications Safety: UL/cUL 508, EN 60950-1 (LVD) EMC: EN 55022, EN 55024 EMI: CISPR 22, FCC Part 15B Class A EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 Rail Traffic: EN 50155 (essential compliance*), EN 50121-4, EN 45545-2 *Moxa defines “essential compliance” to include those EN 50155 requirements that make products more suitable for rolling stock railway applications. Shock: EN 50155, EN/IEC 61373 Freefall: IEC 60068-2-32 Vibration: EN 50155, EN/IEC 61373 Note: Please check Moxa’s website for the most up-to-date certification status. MTBF (mean time between failures) Time: 556,025 hrs Standard: Telcordia SR332 Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty Dimensions Unit: mm (inch) 235 (9.25) 93 (3.66) 103 (4.06) Ø4.5 (Ø0.18) M 4 M 4 M4 M4 M4 M4 M4 M4 M 4 M 4 M 4 M 4 Ø8 (Ø0.31) 177 (6.97) 37 (1.46) 37 (1.46) 108 (4.25) 250 (9.84) 116.3 (4.58) M6 175.8 (6.92) 170 (6.69) 8 (0.31) 120 (4.72) 21 (0.83) 120 (4.72) 21 (0.83) 220 (8.66) Side View (including DIN-Rail Mounting Kit) DIN-Rail Mounting Kit Front View Rear View