5-5 www.mo xa .c o m Industrial Ethernet 5 EDR-G902/G903 Series Industrial Network Security and Management > IPSec VPN: Protocols: • IPSec • L2TP (server) • PPTP (client) Encryption: • DES, 3DES, AES-128, AES-192, AES-256 Authentication: • RSA (key size: 1024-bit, 2048-bit) • X.509 v3 certificate • MD5 and SHA (SHA-256) Throughput: • EDR-G902: Max. 60 Mbps (Condition: AES-246, SHA-256) • EDR-G903: Max. 150 Mbps (Condition: AES-246, SHA-256) Concurrent VPN Tunnels: • EDR-G902: 50 IPSec VPN Tunnels (Max. 15 start in initial mode) • EDR-G903: 100 IPSec VPN Tunnels (Max. 30 start in initial mode) OpenVPN: Protocols: • OpenVPN (client and server), UDP and TCP • Tunnel mode (routing) and TAP mode (bridge) Encryption: • Blowfish CBC, DES CBC, DES-EDE3 CBC, AES-128/192/256 CBC Authentication: • User password by MD5 and SHA1 Concurrent VPN Tunnels: • Server mode: max. 5 external clients • Client mode: max. 2 external servers Real-Time Firewall / VPN Event Log: • Event Type: Firewall Event, VPN Event, System Security Event • Media: Local storage, Syslog server, and SNMP trap Interface WAN/WAN1: 1 RJ45/Fiber combo port WAN2/DMZ: 1 RJ45/Fiber combo port LAN: EDR-G903: RJ45/SFP combo port EDR-G902: RJ45 RJ45 Ports: 10/100/1000BaseT(X) auto negotiation speed Fiber Ports: 100/1000BaseSFP slot LED Indicators: PWR1, PWR2, FAULT, 10/100/1000M Alarm Contact: One relay output with current-carrying capacity of 1 A @ 24 VDC Digital Inputs: 1 input • +13 to +30 V for state “1” • -30 to +3 V for state “0” • Max. input current: 8 mA Power Requirements Input Voltage: 12/24/48 VDC, redundant dual inputs Input Current: 0.45 A @ 24 V Overload Current Protection: Present Connection: Removable terminal block Reverse Polarity Protection: Present Physical Characteristics Housing: Metal, IP 30 protection Dimensions: 51 x 152 x 131.1 mm (2.01 x 5.98 x 5.16 in) Weight: 1250 g (2.82 lb) Installation: DIN-rail mounting, wall mounting (with optional kit) Environmental Limits Operating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95 % (non-condensing) Standards and Certifications Safety: UL 508 EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class A EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8 Power Automation: IEC 61850-3 (EDR-G903) Marine: DNV (EDR-G902) Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6 Note: Please check Moxa’s website for the most up-to-date certification status. MTBF (mean time between failures) Time: 530,000 hrs Standard: Telcordia (Bellcore), GB Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty