10-3 www.mo xa .c o m Product Selection Guide Serial-to-Ethernet Device Servers > 10 Serial Connectivity Railway Device Servers NPort 5150AI-M12/ NPort 5150AI-M12-T/ NPort 5150AI-M12-CT NPort 5250AI-M12/ NPort 5250AI-M12-T/ NPort 5250AI-M12-CT NPort 5450AI-M12/ NPort 5450AI-M12-T/ NPort 5450AI-M12-CT Ethernet Interface 10/100BaseT(X) Ports 1 1 1 Connector M12 M12 M12 Serial Interface RS-232/422/485 Ports 1 2 4 Connector DB9 male DB9 male DB9 male Serial Communication Parameters Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark Flow Control RTS/CTS, DTR/DSR, XON/XOFF Baudrate 50 bps to 921.6 kbps Software Network Protocols ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, IGMP V1/2, LLDP, ARP Configuration Options Web Console, Telnet Console, Windows Search Utility Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded Fixed TTY Drivers SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X Linux Real TTY Drivers Linux 2.4.x, 2.6.x, 3.x Physical Characteristics Housing Metal, IP40 protection Weight 686 g (1.51 lb) Dimensions 80 x 216.6 x 52.9 mm (3.15 x 8.53 x 2.08 in) Environmental Limits Operating Temperature Standard Temperature -25 to 55°C (-13 to 131°F) Wide Temperature -40 to 75°C (-40 to 167°F) Operating Humidity 5 to 95% (non-condensing) Storage Temperature -40 to 85°C (-40 to 185°F) Power Requirements Input Voltage 12 to 48 VDC Input Current 310 mA @ 12 VDC 360 mA @ 12 VDC 440 mA @ 12 VDC Connector M12 Standards and Certifications Safety UL 60950-1 EMC EN 55022/24 EMI CISPR 22, FCC Part 15B Class A EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power 2 kV; Signal 2 kV IEC 61000-4-5 Surge: Power 0.5 kV; Signal: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz, 10 V/m; Signal: 10 V/m IEC 61000-4-8 PFMF Rail Traffic EN 50155 (essential compliance*), EN 50121-4 Vibration IEC 60068-2-6 Reliability Comformal Coating Yes (-CT model only) Yes (-CT model only) Yes (-CT model only) Buzzer, RTC, WDT Yes Yes Yes MTBF Time: 789,341 hrs Standard: Telcordia (Bellcore) Standard TR/SR Time: 639,622 hrs Standard: Telcordia (Bellcore) Standard TR/SR Time: 467,777 hrs Standard: Telcordia (Bellcore) Standard TR/SR Warranty 5 years (see www.moxa.com/warranty) Page 10-18 10-18 10-18 *Moxa defines “essential compliance” to include those EN 50155 requirements that make products more suitable for rolling stock railway applications.