10-39 www.mo xa .c o m NPort® 5600 Series Serial-to-Ethernet Device Servers > 10 Serial Connectivity Dimensions Unit: mm (inch) Power Requirements Input Voltage: NPort 5610/5630/5650: 100 to 240 VAC, 47 to 63 Hz NPort 5610-48V: ±48 VDC (20 to 72 VDC, -20 to -72 VDC) NPort 5650-HV: 110 VDC (88 to 300 VDC) Input Current: NPort 5610-8/16: 141 mA @ 100 VAC, 47 to 63 Hz NPort 5630-8/16: 152 mA @ 100 VAC, 47 to 63 Hz NPort 5610-8/16-48V: 135 mA @ 48 VDC NPort 5650-8/16: 158 mA @ 100 VAC, 47 to 63 Hz NPort 5650-8/16-S-SC: 164 mA @ 100 VAC, 47 to 63 Hz NPort 5650-8/16-M-SC: 174 mA @ 100 VAC, 47 to 63 Hz NPort 5650-8/16-HV: 152 mA @ 88 VDC Standards and Certifications Safety: UL 60950-1 EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class A EMS: NPort 5650-8/16 Series: IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2.5 kV; Signal: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs NPort 5650-8/16-HV Series: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF Medical: EN 60601-1-2 Class B, EN 55011 Reliability Automatic Reboot Trigger: Built-in WDT (watchdog timer) MTBF (mean time between failures) Time: NPort 5610-8: 97,294 hrs NPort 5610-16: 94,928 hrs NPort 5610-8-48V: 96,758 NPort 5630-8: 118,405 hrs NPort 5630-16: 91,483 hrs NPort 5650-8: 117,584 hrs NPort 5650-16: 104,767 hrs NPort 5650-8-S-SC: 116,914 hrs NPort 5650-8-M-SC: 116,914 hrs NPort 5650-16-S-SC: 87,528 hrs NPort 5650-16-M-SC: 87,528 hrs NPort 5650-8-HV: 725,390 hrs NPort 5650-16-HV: 531,264 hrs NPort 5610-16-48V: 926,643 hrs Standard: NPort 5610-8/5610-16/5610-8-48V/NPort 5630-8/5630-16/5650-8/5650-16/5650-8-S-SC/5650-8-M-SC/5650- 16-S-SC/5650-16-M-SC: MIL-HDBK-217F NPort 5650-8-HV/5650-16-HV/5610-16-48V: Telcordia (Bellcore) Standard TR/SR Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty 198 (7.8) LA N 440 (17.3) 480 (19) 45 (1.77) LA N Wide Temp. Model Standard Model AC Model DC/HV Model DC(88-300V) V+ V-