12-58 www. m oxa. com in fo @ mo xa .c o m Multiport Serial Boards > C104H/HS Multiport Serial Boards 12 CI-132 Series The CI-132 series ISA boards come with 2 independent RS-422/485 serial ports for connecting data acquisition equipment and other serial devices to a PC. Connect your devices over longer distances— up to 1.2 km (4000 ft)—and ensure greater reliability in industrial environments with on-board surge protection and electrical isolation (available with some models). Enjoy greater versatility by using point-to-point full-duplex connections, or set up a half-duplex RS-485 multidrop network. 2-port RS-422/485 ISA serial boards › ›Economical RS-422/485 ISA boards with two DB9 male connectors on the board for easy wiring › ›RS-485 data direction control with ADDC® or by RTS › ›921.6 kbps maximum baudrate for super fast data transmission › ›16-byte FIFO and on-chip hardware flow control › ›Surge protection and electrical isolation available › ›Built-in termination resistors Hardware Comm. Controller: 16C550C or compatible x 2 Bus: 16-bit ISA Connectors: DB9 male x 2 Serial Interface Number of Ports: 2 Serial Standards: RS-422/485 Max. No. of Boards per PC: 4 Serial Line Protection ESD Protection: 25 kV on the board (CI-132IS only) Electrical Isolation: 2 kV (CI-132I/IS only) Performance Baudrate: 50 bps to 921.6 kbps Built-in Termination Resistor: 120 ohm (enabled by jumper for RS-485-2w) Serial Communication Parameters Data Bits: 5, 6, 7, 8 Stop Bits: 1, 1.5, 2 Parity: None, Even, Odd, Space, Mark I/O Address: 0x0000-0xFFFF (default = 0x180) IRQ: 2 (9), 3, 4, 5, 7, 10 (default), 11, 12, 15 Serial Signals RS-422: TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND RS-485-2w: Data+(B), Data-(A), GND RS-485 Data Control: ADDC® (automatic data direction control), or by RTS Physical Characteristics Dimensions: CI-132: 75 x 157 mm (2.95 x 6.18 in) CI-132I/IS: 105 x 157 mm (4.13 x 6.18 in) Driver Support Windows: Windows 95/98/ME/NT/2000, Windows XP/2003/ Vista/2008/7/8/8.1 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded Linux: Linux 2.4.x, 2.6.x, 3.x Unix-like Systems: QNX 6, SCO OpenServer, UnixWare 7, Solaris 10, FreeBSD Note: Please refer to Moxa’s website for the latest driver support information. Environmental Limits Operating Temperature: 0 to 55°C (32 to 131°F) Storage Temperature: -20 to 85°C (-4 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Standards and Certifications EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class B EMS: IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Signal: 2 kV MTBF (mean time between failures) Time: 441,015 hrs Standard: Telcordia (Bellcore) TR/SR Power Requirements Input Current: CI-132: 240 mA @ 5 VDC CI-132I/IS: 620 mA @ 5 VDC Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty Available Models CI-132: 2-port RS-422/485 ISA serial board CI-132I: 2-port RS-422/485 ISA serial board with electrical isolation CI-132IS: 2-port RS-422/485 ISA serial board with electrical isolation and surge protection Connection Options (can be purchased separately) CBL-F9M9-150: DB9-F to DB9-M serial cable, 150 cm CBL-F9M9-20: DB9-F to DB9-M serial cable, 20 cm Package Checklist • 1 CI-132 board • Documentation and software CD • Quick installation guide (printed) • Warranty card Specifications Overview Ordering Information