Product Selection Guide Serial Media Converters > Serial Media Converters 14-6 www. m oxa. com 14 CAN-to-Fiber, PROFIBUS-to-Fiber Converters ICF-1170I-M-ST ICF-1170I-M-ST-T ICF-1180I-M-ST/ST-T ICF-1180I-S-ST/ST-T ICF-1280I-M-ST/ST-T ICF-1280I-S-ST/ST-T Optical Fiber Side Fiber Connector ST Cable Requirements Multi-mode: 50/125, 62.5/125, or 100/140 μm Transmission Distance Up to 2 km Multi-mode: 4 km Single-mode: 45 km Multi-mode: 4 km Single-mode: 45 km Wavelength Multi-mode: 850 nm Multi-mode: 820 nm Single-mode: 1310 nm Multi-mode: 820 nm Single-mode: 1310 nm Tx Output Multi-mode: > -5 dBm Multi-mode: > -14 dBm Single-mode: > -7 dBm Multi-mode: > -14 dBm Single-mode: > -7 dBm Rx Sensitivity Multi-mode: -20 dBm Multi-mode: -28 dBm Single-mode: -29 dBm Multi-mode: -28 dBm Single-mode: -29 dBm Fieldbus Interface Connector 3-pin removable screw terminal DB9 female DB9 female Specification CAN 2.0A and 2.0B (ISO 11898-2) PROFIBUS DP (IEC 61158-2) PROFIBUS DP (IEC 61158-2) Signal Support CAN_H, CAN_L, CAN_GND PROFIBUS D+, PROFIBUS D-, RTS, Signal common, 5 V PROFIBUS D+, PROFIBUS D-, RTS, Signal common, 5 V Optical Isolation 2 kV Transfer Rate Up to 1 Mbps Up to 12 Mbps Up to 12 Mbps Termination Resistors 120 ohms (selected by DIP switch) Physical Characteristics Housing Metal Weight 178 g (0.39 lb) 164 g (0.36 lb) 308 g (0.68 lb) Dimensions 30.3 x 115 x 70 mm (11.9 x 45.3 x 27.6 in) 39 x 115 x 70 mm (1.54 x 45.3 x 2.76 in) Environmental Limits Operating Temperature Standard Temperature 0 to 60°C (32 to 140°F) Wide Temperature -40 to 85°C (-40 to 185°F) -40 to 75°C (-40 to 167°F) -40 to 75°C (-40 to 167°F) Ambient Relative Humidity 5 to 95% (non-condensing) Storage Temperature -40 to 85°C (-40 to 185°F) -40 to 75°C (-40 to 167°F) -40 to 75°C (-40 to 167°F) Power Requirements Input Voltage 12 to 48 VDC dual power inputs for redundant power Input Current 221 mA @ 12 VDC 186 mA @ 12 VDC 315 mA @ 12 VDC Voltage Reversal Protection Protects against V+/V- reversal Over Current Protection 1.1 A (protects against two signals shorted together) Standards and Certifications Safety UL 508, EN 60950-1 UL 508, EN 60950-1 UL 508, EN 60950-1 EMC EN 55022/24 EMI CISPR 22, FCC Part 15B Class B A CISPR 22, FCC Part 15B Class B A CISPR 22, FCC Part 15B Class B A EMS EN 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV EN 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV EN 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV EN 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 PFMF EN 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV EN 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m EN 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV EN 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV EN 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m EN 61000-4-8 PFMF EN 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV EN 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m EN 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV EN 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV EN 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m EN 61000-4-8 PFM) Freefall IEC 60068-2-32 IEC 60068-2-32 IEC 60068-2-32 Green Product RoHS, CRoHS, WEEE RoHS, CRoHS, WEEE RoHS, CRoHS, WEEE Reliability MTBF Time: 792,085 hrs Standard: Telcordia (Bellcore), GB Time: 1,870,854 hrs Standard: Telcordia (Bellcore), GB Time: 1,567,875 hrs Standard: Telcordia (Bellcore), GB Warranty 5 years (see www.moxa.com/warranty) Page 14-30 14-32 14-32