Device Connectivity 14-11 www.mo xa .c o m Device Connectivity Serial Media Converters > ICF-1150 Series 14 Pull High/Low Resistor Values Position 0 1 2 3 4 5 6 7 8 9 ohms 150k 10k 4.7k 3.3k 1k 909 822 770 500 485 ICF-1150 Series The ICF-1150 series support 2 serial ports, with a DB9 connector for RS-232 communication and a removable terminal block for RS-422 or RS-485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data through the other 2 ports. For example, once the ICF-1150 converter receives a command from The RS-485 interface supports multidrop or daisy-chain connections, which system engineers will use to connect serial devices such as meters, RTUs, and readers, together on the same bus. Since the number of serial devices on the same bus will cause the impedance the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer’s serial port to the RS-485 bus. of the data line to increase, the ICF-1150 allows users to tune the pull high/low resistor. Just rotate the switch to the appropriate value without removing the ICF-1150 from the DIN rail. Three-Way Communication Rotary Switch for Setting the Pull High/Low Resistor Specifications Industrial RS-232/422/485 to fiber converters › ›3-way communication: RS-232, fiber, and RS-422/485 › ›Rotary switch to change the pull high/low resistor value › ›Extend RS-232/422/485 transmission up to: • 40 km with single-mode • 5 km with multi-mode › ›3-way isolation protection (for “I” models only) › ›-40 to 85°C wide temperature range models available › ›C1D2, ATEX, and IECEx certified for harsh industrial environments Optical-Fiber Side Fiber Connector: SC or ST Fiber Cable Requirements: Low-Speed Fiber Module Multi-Mode Single-Mode Fiber Cable Requirements 50/125 μm, 800 MHz G.652 62.5/125 μm, 500 MHz Typical Distance 5 km 40 km Wave- length Typical (nm) 850 1310 TX Range (nm) 840 to 860 1290 to 1330 RX Range (nm) 800 to 900 1100 to 1650 Optical Power TX Range (dBm) 0 to -5 0 to -5 RX Range (dBm) 0 to -20 0 to -25 Link Budget (dB) 15 20 Dispersion Penalty (dB) 1 1 Note: When using a power meter to measure the fiber TX power, set the baudrate to 9,600 bps and send data (00, …, 0h) to the serial converter’s serial port. Ring Transmission: Half-duplex Point-to-Point Transmission: Half-duplex or full-duplex RS-232/422/485 Side RS-232 Signals: TxD, RxD, GND RS-422 Signals: TxD+, TxD-, RxD+, RxD-, GND RS-485-4w Signals: TxD+, TxD-, RxD+, RxD-, GND RS-485-2w Signals: Data+, Data-, GND Baudrate: 50 bps to 921.6 kbps Isolation: 2 kV RMS isolation per I/O port for 1 minute Physical Characteristics Housing: Metal Dimensions: 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in) Weight: 330 g (0.73 lb)