ICF-1150 Series Serial Media Converters > Serial Media Converters 14-12 www. m oxa. com 14 Environmental Limits Operating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Power Requirements Input Voltage: 12 to 48 VDC Input Current: ICF-1150: 127 mA @ 12 VDC ICF-1150I: 163 mA @ 12 VDC Voltage Reversal Protection: Protects against V+/V- reversal Overcurrent Protection: 1.1 A (protects against two signals shorted together) Standards and Certifications Safety: UL 508 Hazardous Location: UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC, IECEx EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class B EMS: EN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 4 kV; Signal: 2 kV EN 61000-4-5 (Surge): Power: 4 kV; Signal: 0.5 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) Green Product: RoHS, CRoHS, WEEE Freefall: IEC 60068-2-32 MTBF (mean time between failures) Time: 792,085 hrs Standard: Telcordia (Bellcore), GB Water and Dust Proof: IP30 Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty Dimensions Unit: mm (inch) 33.41 (1.32) 48.39 (1.91) 8.8 (0.35) 70 (2.76) 115 (4.53) 8.8 (0.35) 13.66 (0.54) 30.3 (1.20) DB9 female connector Pin RS-232 1 – 2 TxD 3 RxD 4 – 5 GND 6 – 7 – 8 – Pin Assignment Pin RS-422/485-4w RS-485-2w 1 GND GND 2 RxD-(A) Data-(A) 3 RxD+(B) Data+(B) 4 TxD-(A) – 5 TxD+(B) – 5 4 3 2 1 9 8 7 6 1 2 3 4 5 Terminal block connector