17-21 www.mo xa .c o m Remote I/O > ioLogik R1200 Series Remote Automation 17 ioLogik R1214 Specifications Inputs and Outputs Digital Inputs: 6 channels Relays: 6 channels Isolation: 3k VDC or 2k Vrms Digital Input Sensor Type: Wet Contact (NPN or PNP), Dry Contact I/O Mode: DI or Event Counter Dry Contact: • On: short to GND • Off: open Wet Contact (DI to COM): • On: 10 to 30 VDC • Off: 0 to 3 VDC Common Type: 6 points per COM Counter Frequency: 2.5 kHz Digital Filtering Time Interval: Software Configurable Relay Type: Form A (N.O.) power relay Contact Current Rating: Resistive load: 5 A @ 30 VDC, 250 VAC, 110 VAC Breakdown Voltage: 500 VAC Relay On/Off Time: 1500 ms (max.) Initial Insulation Resistance: 1000 mega-ohms (min.) @ 500 VDC Mechanical Endurance: 5,000,000 operations Electrical Endurance: 100,000 operations @ 5 A resistive load Contact Resistance: 100 milli-ohms (max.) Pulse Output: 0.3 Hz at rated load Note: Ambient humidity must be non-condensing and remain between 5 and 95%. The relays of the ioLogik R1214 may malfunction when operating in high condensation environments below 0°C. Power Requirements Input Voltage: 12 to 48 VDC Input Current: 207 mA @ 24 VDC ioLogik R1241 Specifications Inputs and Outputs Analog Outputs: 4 channels Isolation: 3k VDC or 2k Vrms Analog Output Resolution: 12 bits Output Range: 0 to 10 VDC, 0 to 20 mA, 4 to 20 mA Voltage Output: 10 mA (max.) Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C Load Resistor: Internal register: 400 ohms Note: 24 V of external power required when loading exceeds 1000 ohms. Power Requirements Input Voltage: 12 to 48 VDC Input Current: 343 ma @ 24 VDC Inputs and Outputs Analog Inputs: 8 channels Isolation: 3k VDC or 2k Vrms Analog Input Type: Differential input Resolution: 16 bits I/O Mode: Voltage / Current (jumper selectable) Input Range: 0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA (burn-out mode) Accuracy: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C ±0.5% FSR @ -40 and 75°C ioLogik R1240 Specifications Sampling Rate: • All channels: 12 samples/sec • Per channel: 1.5 samples/sec • Only one channel enabled: 12 samples/sec Input Impedance: 10 mega-ohms (min.) Built-in Resistor for Current Input: 120 ohms Power Requirements Input Voltage: 12 to 48 VDC Input Current: 216 mA @ 24 VDC Wet Contact (DI to COM): • On: 10 to 30 VDC • Off: 0 to 3 VDC Common Type: 8 points per COM Counter Frequency: 2.5 kHz Digital Filtering Time Interval: Software Configurable Digital Output Type: Sink I/O Mode: DO or Pulse Output Pulse Output Frequency: 5 kHz Over-Voltage Protection: 45 VDC Over-Current Protection: 2.6 A (4 channels @ 650 mA) Over-Temperature Shutdown: 175°C (typical), 150°C (min.) Current Rating: 200 mA per channel Power Requirements Input Voltage: 12 to 48 VDC Input Current: 187 mA @ 24 VDC Common Specifications Serial Interface: 2 RS-485-2w terminal block ports Serial Line Protection: • ESD Protection: 15 kV • Surge Protection: 1 kV • High/Low Resistor for RS-485: 1 kΩ, 150 kΩ Parity: None, Even, Odd Data Bits: 8 Stop Bits: 1, 2 Baudrate: 1200 to 921600 bps Protocols: Modbus RTU (slave) Physical Characteristics Wiring: I/O cable max. 16 AWG Dimensions: 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in) Weight: Under 200 g (0.44 lb) Mounting: DIN-rail or wall Environmental Limits Operating Temperature: Standard Models: -10 to 75°C (14 to 167°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) Storage Temperature: -40 to 85°C (-40 to 185°F)