44 www.mo xa .c o m General-Purpose Device Servers Serial-to-Ethernet Device Servers > Serial Connectivity General-Purpose Device Servers NPort 5650-8-M-SC NPort 5650-8-S-SC NPort 5650-8-HV-T NPort 5650-16 NPort 5650-16-T NPort 5650-16-M-SC NPort 5650-16-S-SC NPort 5650-16-HV-T Ethernet Interface 10BaseT Ports – – – – – – – 10/100BaseT(X) Ports – – 1 1 – – 1 100BaseFX Ports 1 (multi-mode) 1 (single-mode) – – 1 (multi-mode) 1 (single-mode) – Connector SC SC RJ45 RJ45 SC SC RJ45 Magnetic Isolation Protection – – 1.5 kV 1.5 kV – – 1.5 kV Serial Interface RS-232 Ports – – – – – – – RS-422/485 Ports – – – – – – – RS-232/422/485 Ports 8 8 8 16 16 16 16 Connector RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 RJ45 2 kV Isolation Protection – – – – – – – Serial Communication Parameters Data Bits: 5, 6, 7, 8; Stop Bits: 1, 1.5, 2; Parity: None, Even, Odd, Space, Mark Flow Control RTS/CTS, XON/XOFF Baudrate 50 bps to 921.6 kbps Software Network Protocols ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, SNTP, ARP, PPP, SLIP,RFC2217 Configuration Options Web Console, Telnet Console, Windows Utility Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded Fixed TTY Drivers SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X Linux Real TTY Drivers Linux 2.4.x, 2.6.x, 3.x Onsite Configuration Mini Screen with Push Buttons   –  (excluding T models)   – Physical Characteristics Housing Metal Weight 3,380 g (7.45 lb) 3,380 g (7.45 lb) 3,720 g (8.20 lb) 3,460 g (7.63 lb) 3,440 g (7.58 lb) 3,440 g (7.58 lb) 3,820 g (8.42 lb) Dimensions 440 x 45 x 198 mm (18.9 x 1.77 x 7.80 in) Environmental Limits Operating Temperature Standard Temperature 0 to 55°C (32 to 131°F) – 0 to 55°C (32 to 131°F) – Wide Temperature – – -40 to 85°C (-40 to 185°F) -40 to 75°C (-40 to 167°F) – – -40 to 85°C (-40 to 185°F) Operating Humidity 5 to 95% (non-condensing) Storage Temperature -20 to 70°C (-4 to 158°F) -40 to 85°C (-40 to 185°F) -40 to 75°C (-40 to 167°F) -20 to 70°C (-4 to 158°F) -40 to 85°C (-40 to 185°F) Power Requirements Input Voltage 100 to 240 VAC, 47 to 63 Hz 100 to 240 VAC, 47 to 63 Hz 110 VDC (88 to 300 VDC) 100 to 240 VAC, 47 to 63 Hz 100 to 240 VAC, 47 to 63 Hz 100 to 240 VAC, 47 to 63 Hz 110 VDC (88 to 300 VDC) Input Current 174 mA @ 100 VAC, 47 to 63 Hz 164 mA @ 100 VAC, 47 to 63 Hz 152 mA @ 88 VDC 158 mA @ 100 VAC, 47 to 63 Hz 174 mA @ 100 VAC, 47 to 63 Hz 164 mA @ 100 VAC, 47 to 63 Hz 152 mA @ 88 VDC Standards and Certifications Safety UL 60950-1 EMC EN 55022/24 EMI CISPR 22, FCC Part 15B Class A EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2.5 kV; Signal: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 Dips IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power 2.5 kV; Signal 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 Dips IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF Medical EN 60601-1-2 Class B, EN 55011 Reliability Buzzer, RTC, WDT  MTBF Time: 116,914 hrs Standard: MIL-HDBK-217F Time: 725,390 hrs Standard: Telcordia (Bellcore) Standard TR/SR 104,767 hrs Time: 87,528 hrs Standard: MIL-HDBK-217F Time: 531,264 hrs Standard: Telcordia (Bellcore) Standard TR/SR Warranty 5 years (see www.moxa.com/warranty)