2-64 www. m oxa. com Introduction to IEC 61850-3 Ethernet Switches 2 Industry-Specific Ethernet Switches > Industry-Specific Ethernet Switches Specifications Technology Standards: IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX Software Features Management: IPv4/IPv6, PRP/HSR, SNMPv1/v2c/v3, DHCP Client, BootP, SMTP, RARP, HTTP, Telnet, LLDP, Flow Control, Back Pressure Flow Control, SNMP Inform, Port Mirror, Fiber Check, Syslog, RMON Filter: Multicast Filter Behavior Redundancy Protocols: PRP/HSR, RSTP Transparent Security: RADIUS, TACACS+, Trusted Access Control, Authentication Certificate (SSL Certificate, SSH Key Regenerate) Time Management: SNTP, NTP Server/Client, IEEE 1588v2 PTP Industrial Protocols: Modbus/TCP MIB: IEC 62439-3 MIB Power Substation: MMS Interface Gigabit Ethernet: 3 x 10/100/1000BaseT(X) ports or 100/1000BaseSFP combo ports Console Port: Ethernet console (10/100/1000 Mbps RJ45), USB-serial console (Type B connector) Storage Port: USB storage (Type A connector for ABC-02-USB) Alarm Contact: 1 relay output with current carrying capacity of 1 A @ 24 VDC Digital Inputs: 1 input with the same ground, but electrically isolated from the electronics • +13 to +30 V for state “1” • -30 to +3 V for state “0” • Max. input current: 8 mA Power Requirements Input Voltage: • WV: 24/48 VDC • HV: 110/220 VDC/VAC Operating Voltage: • WV: 18 to 72 VDC • HV: 88 to 300 VDC, 85 to 264 VAC Input Current: • Max. 0.660/0.360 A @ 24/48 VDC • Max. 0.150/0.080 A @ 110/220 VDC • Max. 0.260/0.170 A @ 110/220 VAC Overload Current Protection: Present Connection: 5-pin terminal block Reverse Polarity Protection: Present Physical Characteristics Housing: Aluminum alloy IP Rating: IP40 protection Dimensions: 80 x 160 x 110 mm (3.15 x 6.30 x 4.33 in) Weight: 1210 g (2.69 lb) Installation: DIN-rail mounting Environmental Limits Operating Temperature: -40 to 85°C (-40 to 185°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Standards and Certifications High Availability Automation Networks: IEC 62439-3 Safety: UL 508 EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A EMS: IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 IEC 61000-4-11 Rail Traffic: EN 50121-4 Electrical Substation: IEC 61850-3, IEEE 1613 MTBF (mean time between failures) Time: PT-G503-PHR-PTP-WV:440,857 hrs PT-G503-PHR-PTP-HV:566,844 hrs Standard: Telcordia TR/SR Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty