1-44 www. m oxa. com EDS-505A/508A/516A Series 1 Industrial Ethernet Switches Industrial Ethernet Switches > EDS-505A/508A Series Side View Front View Rear View DIN-Rail/Panel Mounting Kit 30.0 (1.2) 30.0 (1.2) 15.0 (0.6) 46.0 (1.8) 70.0 (2.8) 30.5 (1.2) 7.8 (0.3) 7.8 (0.3) 105.0 (4.1) 80.2 (3.2) 80.2 (3.2) 35.0 (1.4) 135.0 (5.3) 24.3 (1.0) 9.0 (0.4) 66.8 (2.6) 48.3 (1.9) 24.6 (1.0) 39.4 (1.6) 46.8 (1.8) Dimensions Unit: mm (inch) DIP Switches: Turbo Ring, Master, Coupler, Reserve (EDS-505A/508A series only) Alarm Contact: 2 relay outputs with current carrying capacity of 1 A @ 24 VDC Digital Inputs: 2 inputs with the same ground, but electrically isolated from the electronics. • +13 to +30 V for state “1” • -30 to +3 V for state “0” • Max. input current: 8 mA Optical Fiber 100BaseFX Multi-Mode Single- Mode (40 km) Single- Mode (80 km) Fiber Cable Type OM1 50/125 μm G.652 G.652 800 MHz*Km Typical Distance 4 km 5 km 40 km 80 km Wave- length Typical (nm) 1300 1310 1550 TX Range (nm) 1260 to 1360 1280 to 1340 1530 to 1570 RX Range (nm) 1100 to 1600 1100 to 1600 1100 to 1600 Optical Power TX Range (dBm) -10 to -20 0 to -5 0 to -5 RX Range (dBm) -3 to -32 -3 to -34 -3 to -34 Link Budget (dB) 12 29 29 Dispersion Penalty (dB) 3 1 1 Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power. Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB). Power Requirements Input Voltage: 24 VDC, redundant dual inputs Operating Voltage: 12 to 45 VDC Input Current: EDS-505A: 0.21 A @ 24 V EDS-505A-MM/SS: 0.3 A @ 24 V EDS-508A: 0.22A @ 24 V EDS-508A-MM/SS: 0.31 A @ 24 V EDS-516A: 0.35 A @ 24 V EDS-516A-MM: 0.44 A @ 24 V Overload Current Protection: Present Connection: 2 removable 6-contact terminal blocks Reverse Polarity Protection: Present Physical Characteristics Housing: Metal IP Rating: IP30 protection Dimensions: EDS-505A/508A Series: 80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13 in) EDS-516A Series: 94 x 135 x 142.7 mm (3.7 x 5.31 x 5.62 in) Weight: EDS-505A/508A Series: 1040 g (2.30 lb) EDS-516A Series: 1586 g (3.50 lb) Installation: DIN-rail mounting, wall mounting (with optional kit) Environmental Limits Operating Temperature: Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Standards and Certifications Safety: UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1 Hazardous Location: UL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nA nC IIC T4 Gc EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class A EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 Marine: DNV, GL Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6 Note: Please check Moxa’s website for the most up-to-date certification status. MTBF (mean time between failures) Time: EDS-505A Series: 352,000 hrs EDS-508A Series: 339,000 hrs EDS-516A Series: 247,000 hrs Standard: Telcordia (Bellcore), GB Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty