17-15 www.mo xa .c o m Remote I/O > ioLogik E1200H Series Remote Automation 17 Common Specifications ioLogik E1263H Specifications LAN Ethernet: 2 switched 10/100 Mbps RJ45 ports Protection: 1.5 kV magnetic isolation Protocols: Modbus/TCP (slave), TCP/IP, UDP, DHCP, BOOTP, HTTP Serial Interface: 1 RS-232/422/485 (software selectable) DB9 male port Parity: None Data Bits: 8 Stop Bits: 1 Flow Control: None Baudrate: 300 to 115200 bps Protocols: Modbus RTU (slave) Physical Characteristics Wiring: I/O cable max. 14 AWG Mounting: DIN rail (standard), wall (with optional kit) Environmental Limits Operating Temperature: -40 to 75°C (-40 to 167°F) Storage Temperature: -40 to 85°C (-40 to 185°F) Ambient Relative Humidity: 5 to 95% (non-condensing) Shock: IEC 60068-2-27 Vibration: IEC 60068-2-6 Altitude: Up to 2000 m Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes. Standards and Certifications Safety: UL 508 EMC: EN 55022/24, EN 61000-6-2/6-4 EMI: CISPR 22, FCC Part 15B Class A EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 Maritime: IEC 60945 Green Product: RoHS, CRoHS, WEEE Note: Please check Moxa’s website for the most up-to-date certification status. Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty Inputs and Outputs Configurable DIOs (by software): 24 channels Analog Inputs: 10 channels RTDs: 3 channels Isolation: 3k VDC or 2k Vrms Digital Input Sensor Type: Wet Contact (NPN or PNP), Dry Contact I/O Mode: DI or Event Counter (channels 0 to 7) Dry Contact: • On: short to GND • Off: open Wet Contact (DI to GND): • On: 0 to 3 VDC • Off: 10 to 30 VDC Common Type: 12 points per COM Counter Frequency: 250 Hz Digital Filtering Time Interval: Software configurable Digital Output Type: Sink I/O Mode: DO or Pulse Output (channels 0 to 7) Pulse Output Frequency: 500 Hz Over-Voltage Protection: 45 VDC Over-Current Protection: 2.6 A (4 channels @ 650 mA) Over-Temperature Shutdown: 175°C (typical), 150°C (min.) Current Rating: 200 mA per channel Analog Input Type: Differential input Resolution: 16 bits I/O Mode: Voltage / Current (software selectable) Input Range: 0 to 10 V, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA (burnout detection) Accuracy: • ±0.5% FSR @ 25°C • ±1.0% FSR @ -40 and 75° Sampling Rate (all channels): • All channels: 12 samples/sec • Per channel: 0.9 samples/sec Input Impedance: 10 mega-ohms (min.) Built-in Resistor for Current Input: 120 ohms RTDs Sensor Type: • PT100 ( -200 to 850°C) Input connection: 2- or 3-wire Sampling Rate: • All channels: 12 samples/sec • Per channel: 0.9 samples/sec Resolution: 0.5°C Accuracy: • ±0.5% FSR @ 25°C • ±1.0% FSR @ -40 and 75°C Input Impedance: 625 kilo-ohms Power Requirements Input Voltage: 12 to 48 VDC Input Current: 343 mA @ 24 VDC Physical Characteristics Dimensions: 204 x 113 x 36.3 mm ( 8.03 x 4.45 x 1.43 in) Weight: 945 g (2.08 lb) MTBF (mean time between failures) Time: 180,390 hrs Standard: Telcordia SR332