1-60 www. m oxa. com EDS-205/208 Series 1 Industrial Ethernet Switches Industrial Ethernet Switches > Ordering Information Available Models Port Interface Housing Material Power Range Standard Temperature (-10 to 60°C) 10/100BaseT(X) 100BaseFX Multi-Mode, SC Connector Multi-Mode, ST Connector EDS-205 5 – – Plastic 12 to 48 VDC EDS-208 8 – – Plastic 12 to 45 VDC EDS-208-M-SC 7 1 – Plastic 12 to 45 VDC EDS-208-M-ST 7 – 1 Plastic 12 to 45 VDC Rear View Front View Side View Top & Bottom View 100.0 (3.9) 100.0 (3.9) 100.0 (3.9) 76.2 (3.0) 23.0 (0.9) 12.0 (0.5) 15.0 (0.6) 15.0 (0.6) 32.0 (1.3) 10.5 (0.4) 86.5 (3.4) 40.0 (1.6) 40.0 (1.6) 74.0 (2.9) 24.9 (1.0) 74.0 (2.9) Dimensions Unit: mm (inch) Optional Accessories (can be purchased separately) DR-4524/75-24/120-24: 45/75/120 W DIN-rail 24 VDC power supplies MDR-40-24/60-24: 40/60 W DIN-rail 24 VDC power supplies, -20 to 70°C operating temperature RK-4U: 4U-high 19-inch rack-mounting kit Package Checklist • EDS-205 or EDS-208 switch • Hardware installation guide (printed) • Warranty card Standards and Certifications Safety: EDS-205: UL 508, EN 60950-1 EDS-208 Series: UL 508 EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class A EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 Shock: IEC 60068-2-27 Freefall: IEC 60068-2-32 Vibration: IEC 60068-2-6 Note: Please check Moxa’s website for the most up-to-date certification status. MTBF (mean time between failures) Time: EDS-205: 3,915,945 hrs EDS-208: 401,624 hrs EDS-208-M-SC/ST: 368,353 hrs Standard: Telcordia (Bellcore), GB Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty