www. m oxa. com 7 Industrial Cellular Solutions > OnCell G2111/G2151I Industrial Cellular Solutions 7-22 Front & Rear View Top & Bottom View Side View Dimensions Unit: mm (inch) Ordering Information Package Checklist • OnCell G21x1 cellular modem • 1 GSM/GPRS antenna: ANT-CQB-AHSM-00-3m • Terminal block adapter for power jack connector • Documentation CD • Quick installation guide (printed) • Warranty card Note: An activated SIM card (not included) must be provided by a third party Cellular Service Provider. PIN RS-232 1 DCD 2 TxD 3 RxD 4 DSR 5 GND 6 DTR 7 CTS 8 RTS 1 2 3 4 5 6 7 8 9 DB9 female RS-232 port OnCell G2111 OnCell G2151I 27 (1.06) 123 (4.84) 75 (2.95) 79 (3.11) Standards and Certifications Safety: UL 60950-1 EMC: EN 55022/24 EMI: CISPR 22, FCC Part 15B Class A EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 0.5 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 Radio: FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 511 MTBF (mean time between failures) Time: OnCell G2111/G2111-T: 925,000 hrs OnCell G2151I: 864,000 hrs Standard: Telcordia SR332 Warranty Warranty Period: 5 years Details: See www.moxa.com/warranty Available Models OnCell G2111: 1-port RS-232 GSM/GPRS IP modem, -20 to 55°C operating temperature OnCell G2151I: 1-port RS-232/422/485 GSM/GPRS IP modem, isolation, -20 to 55°C operating temperature OnCell G2111-T: 1-port RS-232 GSM/GPRS IP modem, -25 to 70°C operating temperature Note: Please visit Moxa’s website for a complete list of optional wireless accessories and antennas available for Moxa’s wireless products.